National Instruments DB8F-Bare Wire-40A Switch Cable
The National Instruments DB8F-Bare Wire-40A (Part Number: 781092-02) is a specialized cable intended to link PXI signal insertion switch modules—more especially, the PXI-2512, PXIe-2512, PXI-2514, and PXIe-2514—to a range of applications. In industrial automation installations, it makes signal routing between instruments and devices-under-test (DUT) easier. This cable consists of several components, including a DB8F connector, thumbscrews for secure attachment, cable leg labels for easy identification, and eight unterminated wires for versatile connectivity.
The cable has eight shielded, 8AWG stranded, unterminated wires on one end that terminates with a DB8F connector. The DB8F-Bare Wire-40A cable is appropriate for industrial applications because of its maximum voltage rating of 50 VDC and 30 VACrms. A maximum of 40 A of current can be handled by each wire or pin. Nevertheless, it must not be linked to 115 or 230 VAC mains supply circuits (such as wall outlets). The cable is designed for indoor use only and operates within a temperature range of 0°C to 50°C. It can be safely stored in temperatures ranging from -20°C to 70°C. It complies with Pollution Degree 2 regulations and has a relative humidity operating range of 5% to 85%, non-condensing. With a weight of 1372 g (48.4 oz), the DB8F-Bare Wire-40A cable is sturdy and long-lasting, making it appropriate for use in harsh industrial settings. It is suitable for use at altitudes of up to 2,000 m. For a simple connection to the PXI signal insertion switch modules and the application, the DB8F-Bare Wire-40A cable has pinouts and pin assignments. Precise signal routing is made possible by the fact that every pin on the DB8F connection is associated with a particular channel or function on the switch modules.
Model Name | DB8F-Bare Wire-40A |
---|---|
Part Number(s) | 781092-02 |
Maximum Voltage | 50 VDC, 30 VACrms, CAT I |
Maximum Current | 40 A per wire or pin |
Connector Type | DB8F (8-pin female DSUB) |
Wire Gauge | 8AWG stranded |
Connector Termination | Unterminated wires |
Suitable Switch Modules | PXI-2512, PXIe-2512, PXI-2514, PXIe-2514 |
Application Connectivity | Instruments and Devices-Under-Test (DUT) |
Temperature Range (Operating) | 0°C to 50°C |
Temperature Range (Storage) | -20°C to 70°C |
Relative Humidity (Operating) | 5% to 85%, non-condensing |
Weight | 1372 g (48.4 oz) |
Indoor Use Only | Yes |
National Instruments DB8F-Bare Wire-40A Frequently Asked Questions
Question: What modules is the DB8F-Bare Wire-40A compatible with?
Answer: The DB8F-Bare Wire-40A is compatible with PXI signal insertion switch modules—more especially, the PXI-2512, PXIe-2512, PXI-2514, and PXIe-2514.
Question: What connectors does the DB8F-Bare Wire-40A have?
Answer: This part features 8-pin female D-SUB to 8-pin female D-SUB connectors.
Question: Is the DB8F-Bare Wire-40A capable of signal routing?
Answer: Yes, Every pin on the DB8F connection is associated with a particular channel or function on the switch modules, facilitating precise signal routing.
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
DB8F-Bare Wire-40A
Modular Systems > National Instruments > NI Cables
DB8F-Bare Wire-40A, 8-Pin Bare Wire to 8-Pin DSUB Connectors, NI Switch Cable
1-800-915-6216
- Description
- Technical Specifications
- Frequently Asked Questions
National Instruments DB8F-Bare Wire-40A Switch Cable
The National Instruments DB8F-Bare Wire-40A (Part Number: 781092-02) is a specialized cable intended to link PXI signal insertion switch modules—more especially, the PXI-2512, PXIe-2512, PXI-2514, and PXIe-2514—to a range of applications. In industrial automation installations, it makes signal routing between instruments and devices-under-test (DUT) easier. This cable consists of several components, including a DB8F connector, thumbscrews for secure attachment, cable leg labels for easy identification, and eight unterminated wires for versatile connectivity.
The cable has eight shielded, 8AWG stranded, unterminated wires on one end that terminates with a DB8F connector. The DB8F-Bare Wire-40A cable is appropriate for industrial applications because of its maximum voltage rating of 50 VDC and 30 VACrms. A maximum of 40 A of current can be handled by each wire or pin. Nevertheless, it must not be linked to 115 or 230 VAC mains supply circuits (such as wall outlets). The cable is designed for indoor use only and operates within a temperature range of 0°C to 50°C. It can be safely stored in temperatures ranging from -20°C to 70°C. It complies with Pollution Degree 2 regulations and has a relative humidity operating range of 5% to 85%, non-condensing. With a weight of 1372 g (48.4 oz), the DB8F-Bare Wire-40A cable is sturdy and long-lasting, making it appropriate for use in harsh industrial settings. It is suitable for use at altitudes of up to 2,000 m. For a simple connection to the PXI signal insertion switch modules and the application, the DB8F-Bare Wire-40A cable has pinouts and pin assignments. Precise signal routing is made possible by the fact that every pin on the DB8F connection is associated with a particular channel or function on the switch modules.
Model Name | DB8F-Bare Wire-40A |
---|---|
Part Number(s) | 781092-02 |
Maximum Voltage | 50 VDC, 30 VACrms, CAT I |
Maximum Current | 40 A per wire or pin |
Connector Type | DB8F (8-pin female DSUB) |
Wire Gauge | 8AWG stranded |
Connector Termination | Unterminated wires |
Suitable Switch Modules | PXI-2512, PXIe-2512, PXI-2514, PXIe-2514 |
Application Connectivity | Instruments and Devices-Under-Test (DUT) |
Temperature Range (Operating) | 0°C to 50°C |
Temperature Range (Storage) | -20°C to 70°C |
Relative Humidity (Operating) | 5% to 85%, non-condensing |
Weight | 1372 g (48.4 oz) |
Indoor Use Only | Yes |
National Instruments DB8F-Bare Wire-40A Frequently Asked Questions
Question: What modules is the DB8F-Bare Wire-40A compatible with?
Answer: The DB8F-Bare Wire-40A is compatible with PXI signal insertion switch modules—more especially, the PXI-2512, PXIe-2512, PXI-2514, and PXIe-2514.
Question: What connectors does the DB8F-Bare Wire-40A have?
Answer: This part features 8-pin female D-SUB to 8-pin female D-SUB connectors.
Question: Is the DB8F-Bare Wire-40A capable of signal routing?
Answer: Yes, Every pin on the DB8F connection is associated with a particular channel or function on the switch modules, facilitating precise signal routing.